Minimum distances
Dimension mm
A 400
B 650
C 150
D 20
Technical data
Voltage 220 - 240 V
Frequency 50 - 60 Hz
Appliance class 1
Dimension mm
Height 850 - 870
Width 600
Depth 600
Other technical data
Appliance category: I3B/P
LPG: G30 (3B/P) 50 mbar
Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 26 / 25
Semi-rapid 28 / 29
Rapid 38 / 35
Oven 44
Grill 55
Gas burners for LPG G30 50 mbar
BURNER NORMAL
POWER kW
GAS RATE g/h REDUCED POWER
kW
INJECTOR
MARK 1/100 mm
Rapid 3.0 218.1 0.72 77
Semi-rapid 2.0 145.4 0.43 60
Auxiliary 1.0 72.7 0.35 43
Oven 2.7 196.3 1.0 65
Grill 2.0 145.4 1.5 61