Installation
WARNING!
Refer to Safety chapters.
Location of the appliance
You can install your freestanding appliance
with cabinets on one or two sides and in the
corner.
Keep a distance of about 1 cm
between the appliance and the
back wall to make sure that the lid
opens.
For minimal distances for fitting check the
table.
A
C
B
Minimum distances
Dimension mm
A 400
B 650
C 150
Technical data
Dimension mm
Height 850 - 870
Width 900
Depth 600
Appliance class 1
Other technical data
Appliance category: II2H3B/P
LPG: G30 (3B/P) 28-30 mbar
Natural Gas: G20 (2H) 20 mbar
Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
19